What was found
L/WING FIXED L/E VERT SPT ANGLE CRACKED, LWR END, AT WBL 92. STOP DRILLED CRACK, FABRICATED REPAIR ANGLE FROM 7075T6, .063 INCH BY 7.25 INCH BY 2.5 INCH, AND INSTALLED PER B727 SRM 51-10-1, 57-10-2 FIG 3, AND 51-40-3 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L/WING FIXED L/E VERT SPT ANGLE CRACKED, LWR END, AT WBL 92. STOP DRILLED CRACK, FABRICATED REPAIR ANGLE FROM 7075T6, .063 INCH BY 7.25 INCH BY 2.5 INCH, AND INSTALLED PER B727 SRM 51-10-1, 57-10-2 FIG 3, AND 51-40-3 FIG 1.