What was found
CUT OUT DAMAGED STRINGER, BS 1040 TO 1060, ON STR 27L. FABRICATED, AND INSTALLED STR REPAIR PER B727 SRM 53-10-2 FIG 9 AND 53-10-3 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CUT OUT DAMAGED STRINGER, BS 1040 TO 1060, ON STR 27L. FABRICATED, AND INSTALLED STR REPAIR PER B727 SRM 53-10-2 FIG 9 AND 53-10-3 FIG 1.