What was found
FRAME GOUGED AND DENTED AT BS 500 ABOVE STR 17R. CUT OUT DAMAGED AREA. FABRICATED AND INSTALLED FRAME REPAIR FROM 7075T6, .063 INCH BY 7.25 INCH BY 3.25 INCH, PO NR 9006027, PER B727 SRM 53-10-2 FIG 3 AND 51-40-3 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME GOUGED AND DENTED AT BS 500 ABOVE STR 17R. CUT OUT DAMAGED AREA. FABRICATED AND INSTALLED FRAME REPAIR FROM 7075T6, .063 INCH BY 7.25 INCH BY 3.25 INCH, PO NR 9006027, PER B727 SRM 53-10-2 FIG 3 AND 51-40-3 FIG 1.