RT I/B FORE FLAP I/B L/E CHAFED AT RWBL 73. DAMAGE BEYOND SERVICE LIMITS. REMOVED, FABRICATED, AND INSTALLED SKIN PANEL, 2024-T3 .050 INCH BY 14 INCH BY 14.5 INCH, PONR 9006586, PER B727 SRM 57-50-2 FIG 3, 51-20-1, AND 51-30-2.