What was found
FRAME DENTED AND GOUGED IN CARGO COMPT AT BS 660, ABOVE STR 17R. CUT OUT DAMAGE, FABRICATED FRAME REPAIR, AND INSTALLED PER B727 SRM 51-40-3 FIG 1, 53-10-2 FIG 3, AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME DENTED AND GOUGED IN CARGO COMPT AT BS 660, ABOVE STR 17R. CUT OUT DAMAGE, FABRICATED FRAME REPAIR, AND INSTALLED PER B727 SRM 51-40-3 FIG 1, 53-10-2 FIG 3, AND 51-30-2.