What was found
DURING C CHECK, AFT STAIRWELL LIGHTENING HOLE CRACKED 5 O'CLOCK POSITION RIGHT SIDE BS 1265 (TORQUE BOX). CUT OUT DAMAGED AREA AT AFT STAIRWELL LIGHTENING HOLE DIMENSION 1" BY .75" IAW SRM 51-40-2 FIG 1. FABRICATED DOUBLER REPAIR IAW SRM 53-10-2 FIG 6 AND 51-40-2 FIG 1. DRILLED HOLES AT NEW DOUBLER IAW SRM 51-30-5. TREATED AND PRIMED PART AND AREA IAW SRM 51-10-2. INSTALLED DOUBLER REPAIR IAW SRM 51-30-2.