What was found
DURING C CHECK, RIGHT WING NR 6 SLAT TRAILING EDGE GOUGED AT HOOK FITTINGS WS 150 APPROXIMATE. REMOVED HOOK FITTING FROM ACCESS IAW SRM 51-30-2. FABRICATED REPAIR DOUBLER IAW SRM 57-50-3 FIGURE 10. TREATED AND PRIMED DOUBLER AND AREA IAW SRM 51-10-2. INSTALLED REPAIR DOUBLER IAW SRM 51-30-2 AND 57-50-3 FIGURE 10. REINSTALLED HOOK FITTING AT RT WING NR 6 SLAT TRAILING EDGE WS 520 IAW SRM 51-30-2.