What was found
REMOVE AND REPLACE EXISTING REPAIR AT FUSELAGE STA 1260 LONGERON 31L TO 29L WITH A PERMANENT TYPE REPAIR PER SRM OR APPROVED DATA. INDICATE TYPE OF REPAIR, REINSPECTION INTERVAL AND NEXT REQUIRED INSPECTION (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-1 FIG 7 SHEET 1,4,5. REMOVED EXISTING REPAIR NOT ACCORDING TO SRM IAW SRM 51-1-21, SRM 51-1-20D. CUT OUT DAMAGED SECTION AND FABRICATED REPAIR DOUBLER (AL7075T6 0.125") FILLER (AL7075T6 0.100") AND (2EA) INTERNAL FINGER DOUBLER (AL7075T6 0.050") IAW SRM 53-2-1 FIG 7 SHEET 1, 4, 5, SRM 53-4-1 FIG 17A SHEET 1 ITEM "C". CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. INSTALLED REPAIR PARTS IAW SRM 53-2-1 FIG 7 SHEET 1, 4, 5, SRM 51-1-21, SRM 51-1-20D, SRM 51-3-1 (TORQUE). THIS IS A CLASS 1 REPAIR (PERMANENT) INITIAL INSP: 4.000 LANDING CYCLES, REPETITIVE: 4.000 LANDING CYCLES, REPLACEMENT: N/A, METHOD: EXT VISUAL, NEXT INSP: 32448 LANDING CYCLES IAW SRM 53-2-1 FIG. 5 TR# 53-190 DATE 09-20-03