What was found
AT D-CHECK, AFT SIDE OF STA 1183 BULKHEAD HORIZONTAL Z-ANGLE AT RBL 22 HAS BEEN CHAFED BY VERTICAL FRAME ANGLE. INSTALLED ANGLE REPAIR PER SRM 51-40-3, 1.25 INCHES BY 1 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, AFT SIDE OF STA 1183 BULKHEAD HORIZONTAL Z-ANGLE AT RBL 22 HAS BEEN CHAFED BY VERTICAL FRAME ANGLE. INSTALLED ANGLE REPAIR PER SRM 51-40-3, 1.25 INCHES BY 1 INCH.