What was found
AT D-CHECK, FOUND NON-CONFORMING PREVIOIUS REPAIR AT FS 500 BETWEEN STR 15-16R. REINSTALLED REPAIR PER SRM 53-30-3. FILLER, 3 INCHES BY 2 INCHES, DOUBLER, 8 INCHES BY 12 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, FOUND NON-CONFORMING PREVIOIUS REPAIR AT FS 500 BETWEEN STR 15-16R. REINSTALLED REPAIR PER SRM 53-30-3. FILLER, 3 INCHES BY 2 INCHES, DOUBLER, 8 INCHES BY 12 INCHES.