What was found
AT D-CHECK, FOUND FLOOR BOARD SUPPORT BEAM HAS CORROSION AT STA 1135 BETWEEN LBL 50 AND LBL 60. REMOVED AND REPLACED NEW SUPPORT CHANNEL PER SRM 51-10-1 AND SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, FOUND FLOOR BOARD SUPPORT BEAM HAS CORROSION AT STA 1135 BETWEEN LBL 50 AND LBL 60. REMOVED AND REPLACED NEW SUPPORT CHANNEL PER SRM 51-10-1 AND SRM 51-30-2.