What was found
AT C-CHECK, FLOOR SUPPORT WEB AT STA 326 AT LBL 40 CORRODED. REMOVED AND REPLACED SUPPORT WEB PER SRM 51-10-1, 20 INCHES LONG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FLOOR SUPPORT WEB AT STA 326 AT LBL 40 CORRODED. REMOVED AND REPLACED SUPPORT WEB PER SRM 51-10-1, 20 INCHES LONG.