What was found
AT C-CHECK, CABIN FLOORBEAM BS 328 LBL 30 IS CORRODED AT FLOORBEAM SUPPORT ANGLE ATTACH POINTS. INSTALLLED ANGLE REPAIRS 17 BY 1.5 BY 1.5, 15.25 BY 1.5 BY 1.5 PER SRM 51-40-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, CABIN FLOORBEAM BS 328 LBL 30 IS CORRODED AT FLOORBEAM SUPPORT ANGLE ATTACH POINTS. INSTALLLED ANGLE REPAIRS 17 BY 1.5 BY 1.5, 15.25 BY 1.5 BY 1.5 PER SRM 51-40-4.