What was found
AT C-CHECK, FOUND CORROSION FLOORBEAM STRAP RBL 24 AT STA 700. CUT OUT CORROSION FROM 690 TO 710, FABRICATED NEW STRAP 48 BY 3, PER SRM 51-10-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FOUND CORROSION FLOORBEAM STRAP RBL 24 AT STA 700. CUT OUT CORROSION FROM 690 TO 710, FABRICATED NEW STRAP 48 BY 3, PER SRM 51-10-1.