What was found
AT C-CHECK, PRESSURE WEB AT 1183 BULKHEAD CRACKED AT FWD SIDE FLOOR LEVEL RBL 49. INSTALLED DOUBLER REPAIR PER SRM 51-40-2, 3 BY 2 AND INSTALLED NEW WEB AT RBL 49 PER SRM 51-40-2, 12.75 BY 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, PRESSURE WEB AT 1183 BULKHEAD CRACKED AT FWD SIDE FLOOR LEVEL RBL 49. INSTALLED DOUBLER REPAIR PER SRM 51-40-2, 3 BY 2 AND INSTALLED NEW WEB AT RBL 49 PER SRM 51-40-2, 12.75 BY 6.