What was found
AT C-CHECK, FOUND FRAME FITTING BS 940 RT SIDE CRACKED AT FLOOR LEVEL BEAM ATTACHMENT FLANGE AFT END I/B. ACCOMPLISHED EDDY CURRENT INSP, REPLACED RIGHT SIDE FITTING PER S/B 53-0118 AND DRAWING 65 15732 AND 65C13539.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FOUND FRAME FITTING BS 940 RT SIDE CRACKED AT FLOOR LEVEL BEAM ATTACHMENT FLANGE AFT END I/B. ACCOMPLISHED EDDY CURRENT INSP, REPLACED RIGHT SIDE FITTING PER S/B 53-0118 AND DRAWING 65 15732 AND 65C13539.