What was found
AT C-CHECK, FOUND EXFOLIATION CORRSOION ON FUSELAGE FRAME AT FLOOR BEAM ATTACH POINT, RIGHT SIDE OF CMPT FLOOR F.S.-52. REPAIRED FRAME IAW DOUGLAS FAX DATED 20 MAY 96 AND ROD SKETCH 96-05-001. REPAIRED FLOOR WEB PER SRM 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FOUND EXFOLIATION CORRSOION ON FUSELAGE FRAME AT FLOOR BEAM ATTACH POINT, RIGHT SIDE OF CMPT FLOOR F.S.-52. REPAIRED FRAME IAW DOUGLAS FAX DATED 20 MAY 96 AND ROD SKETCH 96-05-001. REPAIRED FLOOR WEB PER SRM 51-1-21.