What was found
DURING C-CHECK, C/W RIGHT WING O/B WS 656.5 RIB INSPECTION PER S/B 727-57-127. INSPECTED RIB PER S/B 27-57-127R3 WS 656.5, FOUND RIB CRACKED AT LOWER FLANGE, NR 2 STRINGER AFT OF FORWARD SPAR. STOP DRILLED CRACK AND REPAIRED PER S/B 57-127. REPAIR SIZE 10.5 BY 2.5 BY .75, N/R2015.