What was found
D-CHECK, FUSELAGE FRAME CRACKED AT FASTENER BS804, STR 14R. STOP DRILLED CRACK AND INSTALLED ANGLE REPAIR AT FUSELAGE FRAME 804 STR 14R PER SRM 51-40-3 AND 51-30-2. SIZE OF REPAIR 13 BY 1 BY 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
D-CHECK, FUSELAGE FRAME CRACKED AT FASTENER BS804, STR 14R. STOP DRILLED CRACK AND INSTALLED ANGLE REPAIR AT FUSELAGE FRAME 804 STR 14R PER SRM 51-40-3 AND 51-30-2. SIZE OF REPAIR 13 BY 1 BY 1.