What was found
D-CHECK, STA 560, ABOVE STR 17, INBOARD FLANGE OF RIB IS DENTED AND CRACKED. CUTOUT DAMAGED AREA 5 BY 1.5 PER SRM 53-10-4. INSTALLED FRAME REPAIR AT STA 560 ABOVE STR17R PER SRM 53-10-4. REPAIR SIZE 5.5 BY 14.75.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.