What was found
D-CHECK, STA 500, ABOVE STR17R, INBOARD FLANGE OF RIB DENTED. CUT OUT DAMAGED SECTION 1.25 BY 4 OF RIB AT BS500, ABOVE STR17R. INSTALLED FRAME REPAIR PER SRM 53-10-4. REPAIR SIZE 19 BY 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
D-CHECK, STA 500, ABOVE STR17R, INBOARD FLANGE OF RIB DENTED. CUT OUT DAMAGED SECTION 1.25 BY 4 OF RIB AT BS500, ABOVE STR17R. INSTALLED FRAME REPAIR PER SRM 53-10-4. REPAIR SIZE 19 BY 6.