What was found
D-CHECK, CORROSION ON TOP OF FLOOR FRAME BS 312 LBL36. CUTOUT DAMAGED AREA 9.5 PER SRM 51-40-4 AT BS 312, LBL36. FABRICATED AND INSTALLED T ANGLE 11 IN LENGTH. FABRICATED AND INSTALLED L ANGLE 19 IN LENGTH PER SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
D-CHECK, CORROSION ON TOP OF FLOOR FRAME BS 312 LBL36. CUTOUT DAMAGED AREA 9.5 PER SRM 51-40-4 AT BS 312, LBL36. FABRICATED AND INSTALLED T ANGLE 11 IN LENGTH. FABRICATED AND INSTALLED L ANGLE 19 IN LENGTH PER SRM 53-10-8.