DURING C CHECK, THE NR 1 SLAT ON THE LEFT WING AT THE INBOARD TRACK HAS A CRACK IN RIB SECTION, AT THAT TRACK. STOP DRILLED CRACKS, ACCOMPLISHED HIGH FREQUENCY EDDY CURRENT INSP AND INSTALLED RIB REPAIRS INBOARD AND OUTBOARD PER SRM 57-50-3 FIG 9. SIZE OF REPAIR 5X4. NON ROUTINE 1232.