What was found
AT D-CHECK, FASTENER INSTALLED ON FRAME RADIUS AT BS 440 BETWEEN STR 6L AND 7L. INSTALLED FRAME REPAIR PER SRM 53-10-4, 10 BY 2.33 BY 1.25.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, FASTENER INSTALLED ON FRAME RADIUS AT BS 440 BETWEEN STR 6L AND 7L. INSTALLED FRAME REPAIR PER SRM 53-10-4, 10 BY 2.33 BY 1.25.