What was found
AT D-CHECK, RIGHT GALLEY DOOR CUT OUT FWD FRAME CRACKED BS 636 AND 3 INCHES ABOVE FLOOR LEVEL. STOPPED DRILLED CRACK, HFEC CRACK, INSTALLED CABIN FRAME REPAIR AS PER SRM 53-10-4, 8 BY 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, RIGHT GALLEY DOOR CUT OUT FWD FRAME CRACKED BS 636 AND 3 INCHES ABOVE FLOOR LEVEL. STOPPED DRILLED CRACK, HFEC CRACK, INSTALLED CABIN FRAME REPAIR AS PER SRM 53-10-4, 8 BY 4.