What was found
AT D-CHECK, CORROSION CABIN FLOORBEAM STA 1110 RBL 48 TO RBL 60. CUT DAMAGED SECTION OF FLOORBEAM BS 110 FROM RBL 36 TO O/B END PER SRM 53-10-8, INSTALLED REPAIR PER SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, CORROSION CABIN FLOORBEAM STA 1110 RBL 48 TO RBL 60. CUT DAMAGED SECTION OF FLOORBEAM BS 110 FROM RBL 36 TO O/B END PER SRM 53-10-8, INSTALLED REPAIR PER SRM 53-10-8.