What was found
AT D-CHECK, AFT PIT FUSELAGE CUTOUT FRAME WEB HAS CORROSION ON UNDER SIDE SURFACE STA 1113 BETWEEN STA 27R TO 25R. CUT OUT DAMAGED AREA, INSTALLED WEB REPAIR PER SRM 51-40-2, 4.125 BY 7.625.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, AFT PIT FUSELAGE CUTOUT FRAME WEB HAS CORROSION ON UNDER SIDE SURFACE STA 1113 BETWEEN STA 27R TO 25R. CUT OUT DAMAGED AREA, INSTALLED WEB REPAIR PER SRM 51-40-2, 4.125 BY 7.625.