What was found
AT D-CHECK, FRAME I/B FLANGE HAS ELONGATED HOLE DRILLED AT BS 760, 4 ABOVE FLOOR LEVEL. INSTALLED FRAME REPAIR PER SRM 51-40-3. FILLER 12 X 6' STRAP 14 X 1.25, DOUBLER 14 X 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, FRAME I/B FLANGE HAS ELONGATED HOLE DRILLED AT BS 760, 4 ABOVE FLOOR LEVEL. INSTALLED FRAME REPAIR PER SRM 51-40-3. FILLER 12 X 6' STRAP 14 X 1.25, DOUBLER 14 X 6.