What was found
AT C-CHECK, FRAME I/B FLANGE HAS DEEP DENT AT BS 1090 AND 26L. CUT OUT DAMAGED AREA ON FRAME 2.75 BY 1.25. INSTALLED FRAME REPAIR PER SRM 53-10-4 DOUBLER 14.5 BY 2.375 BY 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FRAME I/B FLANGE HAS DEEP DENT AT BS 1090 AND 26L. CUT OUT DAMAGED AREA ON FRAME 2.75 BY 1.25. INSTALLED FRAME REPAIR PER SRM 53-10-4 DOUBLER 14.5 BY 2.375 BY 1.