AT C-CHECK, FWD CARGO FRAME IS DENTED AND CRACKED AT STA 540 RBL 9. STOP DRILLED CRACK, HFEC CRACK, ENDS IN STOP HOLE. INSTALLED FRAME REPAIR PER SRM 53-10-4, 14 BY 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FWD CARGO FRAME IS DENTED AND CRACKED AT STA 540 RBL 9. STOP DRILLED CRACK, HFEC CRACK, ENDS IN STOP HOLE. INSTALLED FRAME REPAIR PER SRM 53-10-4, 14 BY 3.