What was found
AT C-CHECK, AT STA 620, ANGLE CRACKED BELOW FLOOR PANEL CENTER SECTION. REMOVED CRACKED ANGLE, FABRICATED NEW ANGLE AND INSTALLED PER SRM 51-1-21, 20 IN LENGTH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, AT STA 620, ANGLE CRACKED BELOW FLOOR PANEL CENTER SECTION. REMOVED CRACKED ANGLE, FABRICATED NEW ANGLE AND INSTALLED PER SRM 51-1-21, 20 IN LENGTH.