What was found
MCC, FUS STA 500, LINE NR 1 WORN FLOOR TRACK. CUT OUT DAMAGED AREA AND FABRICATED REPAIR PLUG IAW SRM 53-23 FIG 6D. TREATED AND PRIMED IAW SRM 51-1-8. INSTALLED REPAIR PLUG IAW SRM 53-2-3 FIG 6D INSTALLED FASTENER SRM 51-3-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCC, FUS STA 500, LINE NR 1 WORN FLOOR TRACK. CUT OUT DAMAGED AREA AND FABRICATED REPAIR PLUG IAW SRM 53-23 FIG 6D. TREATED AND PRIMED IAW SRM 51-1-8. INSTALLED REPAIR PLUG IAW SRM 53-2-3 FIG 6D INSTALLED FASTENER SRM 51-3-0.