What was found
MCC, FUS STA 150, LINE NR 2, FLOOR TRACK IS DAMAGED, ABOUT 12 INCHES. CUT OUT DAMAGED AREA AND FABRICATED NEW SEAT TRACK IAW SRM 53-2-3 FIG 14. TREATED AND PRIMED IAW SRM 51-1-8. INSTALLED SEAT TRACK AND SPLICES IAW SRM 53-2-3 FIG 14. INSTALLED FASTENERS IAW SRM 51-3-0.