What was found
MCC, FUS STA 340, LINE NR 4, FLOOR TRACK IS WORN IN TWO PLACES. CUT OUT DAMAGED AREA AND FABRICATED REPAIR PLUG IAW SRM 53-2-3, FIG 6D. TREATED AND PRIMED PARTS AND AREA IAW SRM 51-1-8. INSTALLED REPAIR PLUG IAW SRM 53-2-3 FIG 6D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCC, FUS STA 340, LINE NR 4, FLOOR TRACK IS WORN IN TWO PLACES. CUT OUT DAMAGED AREA AND FABRICATED REPAIR PLUG IAW SRM 53-2-3, FIG 6D. TREATED AND PRIMED PARTS AND AREA IAW SRM 51-1-8. INSTALLED REPAIR PLUG IAW SRM 53-2-3 FIG 6D.