What was found
MCC, FUS STA 1700, FUSE NR , FLOOR TRACK IS DAMAGED, CHIPPED. CUT OUT DAMAGED AREA AND FABRICATED REPAIR PLUG IAW SRM. 53-2-3 F.6D. TREATED AND PRIMED PER SRM 51-1-8, OK TO INSTALL REPAIR, INSTALLED REPAIR STA 1700 SEAT TRACK NR 3 IAW SRM 53-2-3 FIG 6D.