What was found
MCC, FUS STA 860, LINE NR 3, FLOOR TRACK IS WORN. CUT OUT DAMAGED AREA AND FABRICATED REPAIR PLUG IAW SRM 53-2-3 FIG 6D. TREATED AND PRIMED PER SRM 51-1-8. INSTALLED REPAIR STA 860 SEAT TRACK NR 3 IAW, 53-2-3 FIG 6D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCC, FUS STA 860, LINE NR 3, FLOOR TRACK IS WORN. CUT OUT DAMAGED AREA AND FABRICATED REPAIR PLUG IAW SRM 53-2-3 FIG 6D. TREATED AND PRIMED PER SRM 51-1-8. INSTALLED REPAIR STA 860 SEAT TRACK NR 3 IAW, 53-2-3 FIG 6D.