What was found
MCC, FUS STA 1060, LINE NR 5, FLOOR TRACK IS CHIPPED. CUT OUT DAMAGED FLOOR AND REPLACED 10 FT OF SEAT TRACK AND FABRICATED REPAIR SPLICES IAW SRM 53-2-3 FIG 14. TREATED AND PRIMED PARTS IAW SRM 51-1-8. INSTALLED FLOOR TRACK AND SPLICES IAW SRM 53-2-3 FIG 14.