What was found
MCC, FUS STA 1040, FLOOR TRACK IS DAMAGED, 4 PLACES, LINE NR 5. CUT OUT DAMAGED FLOOR TRACK AND REPLACED 10 FT OF SEAT TRACK AND FABRICATED REPAIR SPLICES IAW SM 53-2-3 FIG 14. TREATED AND PRIMED IAW SRM 51-1-8. INSTALLED FLOOR TRACK AND SPLICES IAW SRM 53-2-3 FIG 14.