What was found
LT UPPER L/E MOUNT SURF HAS CORROSION FROM XFS 678. TO XFS 690. REMOVED LEVEL II CORROSION IAW SM 51-1-8 AND FOUND AREA TO BE BEYONG LIMITS, CUT OUT DAMAGED SECTION OF SKIN AND FABRICATED REPAIR DOUBLER AND FILLER IAW SRM 57-2-1F38. CUT OUT DAMAGED SECTION OF SKIN AND FABRICATED REPAIR DOUBLER AND FILLER IAW SM 57-2-1F38. TREATED AND PRIMED FAYING SURFACES IAW SM 51-1-8. INSTALLED REPARIED DOUBLER AND FILLER IAW SRM 57-2-1, FIG 38. SEALED EDGES OF DOUBLER IAW SRM 51-1-15. REPAIR SIZE: 105 BY 6.