What was found
EMPENNAGE AT APPROX STA 141.200 ON L/E OF THE RT HORIZONTAL STAB HAS TWO AREAS OF CORROSION. REMOVED CORROSION LEVEL 2, NEED REPAIR. CUT OUT DAMAGED AREA AND FABRICATED REPAIR PER DER 85530-2. TREATED AND PRIMED PER SRM 51-1-8. INSTALLED REPAIR PER DER 85530-2, SHEET 3.