What was found
AT C CHECK, FLOOR SUPPORT CRACKED BS 848 RBL 27. INSTALLED FORMED ANGLE REPAIR PER SRM 51-40-3, 6 BY 3, N/R 5437.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C CHECK, FLOOR SUPPORT CRACKED BS 848 RBL 27. INSTALLED FORMED ANGLE REPAIR PER SRM 51-40-3, 6 BY 3, N/R 5437.