What was found
AT D CHECK, CRACKED FRAME STA 990 AT STR 26L, CRACK TERMINATED AT FASTENER HOL, VERIFIED BY HFEC. INSTALLED DOUBLER REPAIR PER SRM 53-10-4, 2 FT BY 7, N/R 3558.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D CHECK, CRACKED FRAME STA 990 AT STR 26L, CRACK TERMINATED AT FASTENER HOL, VERIFIED BY HFEC. INSTALLED DOUBLER REPAIR PER SRM 53-10-4, 2 FT BY 7, N/R 3558.