What was found
BS 560 FLOORBEAM LBL 10 LIGHT CORROSION. CUT OUT DAMAGED SECTION, INSTALLED UPPER CHORD REPAIR PER SRM 53-10-8, 10.75. N/R 5188.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 560 FLOORBEAM LBL 10 LIGHT CORROSION. CUT OUT DAMAGED SECTION, INSTALLED UPPER CHORD REPAIR PER SRM 53-10-8, 10.75. N/R 5188.