AT D-CHECK, AFT BAGGAGE FLOOR INTERCOSTAL WEB BENT AND VERTICAL STIFFENER CRACKED AT BL-0 BETWEEN STA 950F AND 970. INSTALLED NEW VERTICAL STIFFENER PER SRM 51-40-3, 12 X 12 X 12. INSTALLED WEB REPAIR PER SRM 51-30-2. N/R 3241.