What was found
AT D-CHECK, STA 660 FRAME INNER FLANGE BETWEEN STR 17R AND 16R HAS DENTS. CUT OUT DAMAGED AREA, INSTALLED FRAME REPAIR PER SRM 53-10-4, 16 X 5 X 1. N/R 3219.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D-CHECK, STA 660 FRAME INNER FLANGE BETWEEN STR 17R AND 16R HAS DENTS. CUT OUT DAMAGED AREA, INSTALLED FRAME REPAIR PER SRM 53-10-4, 16 X 5 X 1. N/R 3219.