What was found
AT C-CHECK, CABIN FLOOR STRUCTURE STA 1150, 25 RBL HAT CHANNEL BROKEN OFF. REPLACED HAT CHANNEL METAL STRAP PER SRM 51-40-2, 11 X 7. N/R 5122.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, CABIN FLOOR STRUCTURE STA 1150, 25 RBL HAT CHANNEL BROKEN OFF. REPLACED HAT CHANNEL METAL STRAP PER SRM 51-40-2, 11 X 7. N/R 5122.