What was found
AT D CHECK, FWD PIT A/C COMPT VERTICAL ANGLE SUPPORT CLIP CRACKED AT STA 720E FLOORBEAM RBL 51. REPLACED CLIP PER SRM 51-30-2, 3.5 BY .5. N/R 3535.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D CHECK, FWD PIT A/C COMPT VERTICAL ANGLE SUPPORT CLIP CRACKED AT STA 720E FLOORBEAM RBL 51. REPLACED CLIP PER SRM 51-30-2, 3.5 BY .5. N/R 3535.