AT D CHECK, FWD BILGE FLOOR SUPPORT Z ANGLE CRACKED AT RADIUS AT STA 520 STR 27R. CUT OUT DAMAGED AREA AND INSTALLED PER SRM 51-40-3, 2', N/R 3620.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT D CHECK, FWD BILGE FLOOR SUPPORT Z ANGLE CRACKED AT RADIUS AT STA 520 STR 27R. CUT OUT DAMAGED AREA AND INSTALLED PER SRM 51-40-3, 2', N/R 3620.