What was found
AT C-CHECK, LT FLAP HINGE SUPPORT FITTING AT STA 97 NR 2 HOLE HAS CRACK. REAMED HOLE AND HFEC NO FURTHER CRACK FOUND PER DC-8 MM 51-3-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, LT FLAP HINGE SUPPORT FITTING AT STA 97 NR 2 HOLE HAS CRACK. REAMED HOLE AND HFEC NO FURTHER CRACK FOUND PER DC-8 MM 51-3-4.