What was found
AT C-CHECK, FUS STA LINE NR 6 FLOOR TRACK WORN. CUT OUT DAMAGED AREA, FABRICATED PLUG AND INSTALLED PER SRM 53-2-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FUS STA LINE NR 6 FLOOR TRACK WORN. CUT OUT DAMAGED AREA, FABRICATED PLUG AND INSTALLED PER SRM 53-2-3.